<LOGO>
FM Transmitter Measurement Report
Created: 2025-01-20 13-35-14
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
106.20 MHz 5/5, 71 dBuV LOOP
Pilot RDS Phase Difference
7.0 kHz 2.8 kHz 30 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 70 kHz 19020 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,9 dBr 5,95 dBr 6,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" LOOP " 6459 25 (Country) 1 0 1 1 --:--
RT
" - "
AF EON
92.9, 94.8, 98.3, 105.1, 106.1, 106.2 MHz -
FM Scope Max at: 70 kHz MIN: 9 kHz % above 76 kHz: 0,0000 Acquired: 2025/01/20 13.34.11 Total samples: 19020 Equivalent time: 0:15:51 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000